As more GN decanter centrifuges are utilizing within the gas and oil industries for that drilling liquids management and water recycling, GN decanter centrifuges are helping a lot of the customers to protect the environment.
Now GN Solids Control is manufacturing about 250 sets to 300 sets each year, many of these decanter centrifuges are utilizing over abroad. To be able to fulfill customers’ demands, GN usually transmits out our engineers for that post sales service.
Things the operators have to know:
1. The wiring have to be fully correct. Any wrong connections can lead to destroy decanter centrifuge, and also the separation work cannot be done.
2. The liquid discharge port shouldn't be transformed without allowance. For uncertain situations, we advise to put a catching tank towards the bottom from the liquid discharge port. When the pipe associated with liquid discharge port is simply too small, liquids is going to be flooded in the small finish and also the VFD control panel can give an end signal towards the primary motor for defense.
3. The first feeding capacity ought to be too big. Although GN drilling fluids decanter centrifuge can treat 130 GPM, different OBM or WBM has different density therefore the dealing with capacity isn't necessarily exactly the same. For that clients have to concern the feeding capacity, we advise to provide a family member small feeding capacity in the beginning. When the solids released in the solids port is fairly dry, the feeding capacity could be elevated. On the other hand, when the solids are with an excessive amount of oil or water after being treating by decanter centrifuge, the operator should reduce the feeding capacity a bit.
4. Clean the decanter centrifuge completely once you finish the separation work. Pour some clean water to feed the centrifuge, some solids left within the collection box is going to be washed. After the cleaning, spin the centrifuge to discharge the water.